Vue de la page 0
OPERATION MANUAL
CM25
SERIAL NUMBER FROM OCTOBER 2009 (1009) TO PRESENT
READ THIS MANUAL CAREFULLY FOR INSTRUCTIONS ON CORRECT
INSTALLATION AND USAGE, AND READ ALL SAFEGUARDS.
SECCIÓN EN ESPAÑOL
SECTION EN FRANÇAIS
AVAILABLE AT WWW.MOVINCOOL.COM
Vue de la page 0
1 2 3 4 5 6 ... 59 60

Résumé du contenu

Page 1 - OPERATION MANUAL

OPERATION MANUALCM25SERIAL NUMBER FROM OCTOBER 2009 (1009) TO PRESENTREAD THIS MANUAL CAREFULLY FOR INSTRUCTIONS ON CORRECTINSTALLATION AND USAGE, AND

Page 2

10INSTALLATION (cont.)Clearance Requirement51.353.0All dimensions are in inches.Unit Weight: 310 lb (140 kg)29.8DIA. 0.64.015.7 DIA. 11.8DIA. 11.814.4

Page 3

11INSTALLATION (cont.)Mounting CM25 to Roof StructureBe sure to securely anchor the top ends of the suspension rods. Make sure all nuts are tight. Be

Page 4 - Table of Contents

12INSTALLATION (cont.)Mounting CM25 to Roof Structure (cont.)Example of Mounting with Pallet1. Install four (4) suspension rods by suspending them fro

Page 5

13INSTALLATION (cont.)Mounting CM25 to Roof Structure (cont.)Example of Mounting with Pallet4. Insert the suspension rods through the mounting holes o

Page 6 - FOREWORD

14INSTALLATION (cont.)Mounting CM25 to Roof Structure (cont.)Example of Mounting without Pallet1. Install four (4) suspension rods by suspending them

Page 7 - UNPACKING

15INSTALLATION (cont.)Mounting CM25 to Roof Structure (cont.)Example of Mounting without Pallet4. Insert the suspension rods through the mounting hole

Page 8 - INVENTORY

16INSTALLATION (cont.)Drain Hose ConnectionThe CM25 is equipped with an internal condensation removal pump with maximum head lift of 4 feet (1.2 m).1.

Page 9 - INSTALLATION

17INSTALLATION (cont.)Drain Hose Connection (cont.)Check following items:• No kinks or bends on the drain hose• No trap in the drain hose• The end of

Page 10 - INSTALLATION (cont.)

18INSTALLATION (cont.)Ducting With Typical Drop CeilingAll hardware is field supplied.CAUTION: Do not operate the unit without the filter installed on

Page 11

19INSTALLATION (cont.)Condenser Duct Installation (Optional)Condenser intake and exhaust ducts can be installed to exchange outdoor air.CAUTION:1. Lou

Page 12

© 2009 DENSO SALES CALIFORNIA, INC.All rights reserved. This book may not be reproduced or copied, in whole or in part, without the written permission

Page 13

20INSTALLATION (cont.)Power Supply and Field Wiring ConnectionWARNING:1. All electrical work should only be performed by qualified personnel. Repair t

Page 14

21INSTALLATION (cont.)Power Supply and Field Wiring Connection (cont.)Field Wiring ConnectionThe following are recommended wire sizes and electrical r

Page 15

22INSTALLATION (cont.)Power Supply and Field Wiring Connection (cont.)4. Route power cord wires through the power cord inlet located below service pan

Page 16

23INSTALLATION (cont.)DIP Switch Configuration and Setting (cont.)SwitchNameSwitchNumberFunctionDSW11ON Enables the millivolt wall thermostat.OFF Enab

Page 17

24INSTALLATION (cont.)Supplied Wall Mounted Controller ConnectionSet up the wall mounted controller without power connection on the unit. Otherwise, t

Page 18

25INSTALLATION (cont.)Supplied Wall Mounted Controller Connection (cont.)3. Connect the supplied shield wire (12 feet) to the 3-pin connector on the c

Page 19

26INSTALLATION (cont.)Supplied Wall Mounted Controller Connection (cont.)4. Depending on installation conditions, there are two methods to insert the

Page 20

27INSTALLATION (cont.)Supplied Wall Mounted Controller Connection (cont.)6. Select the proper location where the controller can be conveniently access

Page 21

28INSTALLATION (cont.)Supplied Wall Mounted Controller Connection (cont.)9. Disconnect power before connecting the wall mounted controller to the unit

Page 22

29INSTALLATION (cont.)Supplied Wall Mounted Controller Connection (cont.)11. DIP switch #1 of DSW1 on the relay board must be in the OFF position to u

Page 23

OPERATION MANUALCM25

Page 24

30INSTALLATION (cont.)Field-Supplied Millivolt Wall Thermostat Connection (cont.)4. Disconnect power before connecting the wall thermostat to the unit

Page 25

31INSTALLATION (cont.)Field-Supplied Millivolt Wall Thermostat Connection (cont.)6. DIP switch #1 of DSW1 on the relay board must be in the ON positio

Page 26

32INSTALLATION (cont.)Warning Signal Connection (Output Signal)The unit is equipped with a warning signal output relay type (Form-C, normal open dry c

Page 27

33INSTALLATION (cont.)Warning Signal Connection (Output Signal) (cont.)4. Connect the warning signal wires to terminal L+ and L- in the unit control b

Page 28

34INSTALLATION (cont.)Fire Alarm Connection (Input Signal)The unit is equipped with a normal open input signal connection, which can be connected dire

Page 29

35INSTALLATION (cont.)Fire Alarm Connection (Input Signal) (cont.)4. Connect the fire alarm signal wires to terminal E+ and E- in the unit control box

Page 30

36FEATURES OF WALL MOUNTED CONTROLLER1. Supplied wall mounted controller allows the user to easily control the unit’s operation.2. LCD display that in

Page 31

37FEATURES OF CM251. The CM25 is equipped with a variable speed compressor, which is driven by state of the art inverter technology. A variable speed

Page 32

38OPERATION (Wall Mounted Controller ONLY)Controller PanelBefore operating the unit, it is important to familiarize yourself with the basic controls l

Page 33

39OPERATION (Wall Mounted Controller ONLY) (cont.)Controller Panel (cont.)1. ON/OFF Button Activates (LED illuminates green) or deactivates unit opera

Page 34

Table of ContentsFOREWORD ... 6Definition of Terms.

Page 35

40OPERATION (Wall Mounted Controller ONLY) (cont.)Controller Panel (cont.)NOTE: The room temperature display range is from 16 °F (-9 °C) to 140 °F (60

Page 36 - CONTROLLER

41OPERATION (Wall Mounted Controller ONLY) (cont.)Standby ModeWhen power source is supplied to the unit, the wall mounted controller is in standby mod

Page 37 - FEATURES OF CM25

42OPERATION (Wall Mounted Controller ONLY) (cont.)Operate in COOL ModeWhen in COOL mode, the compressor is operated and cool air is circulated.1. Pres

Page 38 - Controller Panel

43OPERATION (Wall Mounted Controller ONLY) (cont.)Operate in FAN ONLY ModeWhen in FAN ONLY mode, the unit circulates the surrounding air.1. Press ON/O

Page 39 - OPERATION

44OPERATION (Wall Mounted Controller ONLY) (cont.)Program SettingTo program the controller, read the instructions on page 45 to 47 and follow the flow

Page 40

45OPERATION (Wall Mounted Controller ONLY) (cont.)Select Program Sequence Number1. Press and hold PROGRAM button for 3 seconds. “Pr 01” blinks.Note: I

Page 41

46OPERATION (Wall Mounted Controller ONLY) (cont.)Set Stop Time11. Press UP ( ) or DOWN ( ) button to select “Day of the week”.Press ENTER button. “Ho

Page 42

47OPERATION (Wall Mounted Controller ONLY) (cont.)Edit Program1. Press and hold PROGRAM button for 3 seconds. “Pr 01” blinks.2. Press UP ( ) or DOWN (

Page 43

48OPERATION (Wall Mounted Controller ONLY) (cont.)Program Plan SheetSTARTPr 01STOPSTARTPr 02STOPSTARTPr 03STOPSTARTPr 04STOPSTARTPr 05STOPSTARTPr 06ST

Page 44

49SELF-DIAGNOSTIC CODES & BUZZER PATTERNSelf-Diagnostic CodesSelf-diagnostic codes are displayed with “CHECK” on LCD panel of the supplied wall mo

Page 45

Program Plan Sheet ... 48SELF-DIAGNOSTIC CODES & BUZZER PATTERN...

Page 46

50SELF-DIAGNOSTIC CODES & BUZZER PATTERN (cont.)Buzzer Pattern0.5 sec1 sec4 secPattern 1Pattern 2Pattern 3Pattern 4ONOFFONOFFONOFFONOFF

Page 47

51DAILY INSPECTION & MAINTENANCECleaning Air FiltersThe air filter on the evaporator return grill should be checked weekly for dust buildup.Clean

Page 48

52TROUBLESHOOTINGCheck the following items before calling your MovinCool reseller or a qualified technician.Condition Checking Area Possible Cause Rem

Page 49 - Self-Diagnostic Codes

53TROUBLESHOOTING (cont.)ConditionChecking AreaPossible Cause RemedySelf-Diagnostic Codes(Wall mounted controller)BuzzerPatternUnit does not operate a

Page 50 - PATTERN (cont.)

54TROUBLESHOOTING (cont.)ConditionChecking AreaPossible Cause RemedySelf-Diagnostic Codes(Wall mounted controller)BuzzerPatternUnit does not operate a

Page 51 - Ground Fault Breaker Testing

55TROUBLESHOOTING (cont.)ConditionChecking AreaPossible Cause RemedySelf-Diagnostic Codes(Wall mounted controller)BuzzerPatternUnit does not operate a

Page 52 - TROUBLESHOOTING

56TROUBLESHOOTING (cont.)ConditionChecking AreaPossible Cause RemedySelf-Diagnostic Codes(Wall mounted controller)BuzzerPatternUnit does not operate a

Page 53 - Cause Remedy

57TROUBLESHOOTING (cont.)If conditions persist after the above actions have been taken, turn the unit off, disconnect the power and contact your Movin

Page 54

58TECHNICAL SPECIFICATIONS#1: With two 20 feet (6.1 m) duct with one 90° bend each, supply grill and return grill with filter (0.30 IWG (75 Pa) extern

Page 55

LIMITED WARRANTYDENSO SALES CALIFORNIA, INC. (“DENSO”) warrants its MOVINCOOL Products only to the extent stated in its official written warranties. U

Page 56

6FOREWORDCongratulations on purchasing the MovinCool air conditioner. This manual explains how to assemble, install and operate the MovinCool CM25 air

Page 57

DENSO SALES CALIFORNIA, INC.Long Beach, CA 90810www.movincool.comP/N: 484007-3200EN First Issue: October 2009

Page 58 - TECHNICAL SPECIFICATIONS

7UNPACKINGRemove the package as shown below.Note: The unit can be installed while the unit is on the pallet. (See “Mounting CM25 to Roof Structure” on

Page 59 - LIMITED WARRANTY

8INVENTORYAfter unpacking your MovinCool unit, please check to make sure you have the following items:1. CM25 MovinCool Unit (1)2. Operation Manual/Pr

Page 60 - Long Beach, CA 90810

9INSTALLATIONUnit OverviewWARNING: Remove protective cardboard from condenser air intake after installation.COOL AIR EXHAUST(12 in DIA. FLANGE)DRAIN P