Movincool Classic 60 Spécifications

Naviguer en ligne ou télécharger Spécifications pour Climatiseurs à système divisé Movincool Classic 60. Movincool Classic 60 Specifications Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 46
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
OPERATION MANUAL
CLASSIC 40 and CLASSIC 60
Unit Serial Number Range: 0711XXXX### to Present
(From July 2011 to Present)
READ THIS MANUAL CAREFULLY FOR INSTRUCTIONS ON CORRECT
INSTALLATION AND USAGE, AND READ ALL SAFEGUARDS
SECCIÓN EN ESPAÑOL
SECTION EN FRANÇAIS
AVAILABLE AT WWW.MOVINCOOL.COM
Vue de la page 0
1 2 3 4 5 6 ... 45 46

Résumé du contenu

Page 1 - OPERATION MANUAL

OPERATION MANUALCLASSIC 40 and CLASSIC 60Unit Serial Number Range: 0711XXXX### to Present(From July 2011 to Present)READ THIS MANUAL CAREFULLY FOR INS

Page 2 - Nameplate Label

10INSTALLATION (cont.)Exterior DimensionsClassic 402.837.84xM202.830.141.34.86.95.110.05.125.8DIA. 13.8DIA. 22.010.020.712.943.55.110.24.36XM62X6XM622

Page 3

11INSTALLATION (cont.)Exterior Dimensions (cont.)Classic 608.729.94xDIA. 0.53.533.85.17.131.53.1 25.2 3.1DIA. 25.1DIA. 13.811.522.015.849.431.79.38.58

Page 4 - Table of Contents

12INSTALLATION (cont.)Choosing an Installation SiteCAUTION: Following are some precautions to consider before choosing your installation site. Please

Page 5 - FOREWORD

13INSTALLATION (cont.)Plugging in the Unit (For Classic 40 ONLY)1. Check the prongs and surface of the power cord plug for dust/dirt. If dust and/or d

Page 6 - INVENTORY & ASSEMBLY

14INSTALLATION (cont.)Power Supply and Field Wiring Connection (For Classic 60 ONLY)Power Supply• AC 460 V±10 %, 3 phase and 60 Hz. Do not connect the

Page 7 - Inventory (cont.)

15INSTALLATION (cont.)Power Supply and Field Wiring Connection (For Classic 60 ONLY) (cont.)Power Supply Wires• Use at least 12 AWG for the power wire

Page 8 - M6 BOLTS (8)

16INSTALLATION (cont.)Optional Accessories and Set Up ConfigurationUsing the optional accessories not only gives you the ability to customize the cool

Page 9 - INSTALLATION

17INSTALLATION (cont.)Optional Accessories and Set Up Configuration (cont.)Unit Installed on the Floor (For Classic 40 and Classic 60) 2. Application

Page 10 - DIA. 22.0

18INSTALLATION (cont.)Optional Accessories and Set Up Configuration (cont.)Unit Suspended from the Ceiling (For Classic 40 ONLY)When the unit is suspe

Page 11 - DIA. 26.2

19INSTALLATION (cont.)Optional Accessories and Set Up Configuration (cont.)Unit Suspended from the Ceiling (For Classic 40 ONLY)1. Standard Configurat

Page 12

SERIAL NUMBER LOCATION AND IDENTIFICATIONNameplate Label PositionNameplate LabelCOOLING AMPS. WITH PUMPCOMPR. OUTPUTREFRIGERANT/TOTAL CHARGEDESIGN PRE

Page 13

20INSTALLATION (cont.)Optional Accessories and Set Up Configuration (cont.)Unit Suspended from the Ceiling (For Classic 40 ONLY)2. Application Configu

Page 14

21INSTALLATION (cont.)Optional Accessories and Set Up Configuration (cont.)Unit Suspended from the Ceiling (For Classic 40 ONLY)3. Duct Work Procedure

Page 15

22INSTALLATION (cont.)Optional Accessories and Set Up Configuration (cont.)Unit Used as a Portable TypeThe unit can be used as a portable spot cooling

Page 16

23INSTALLATION (cont.)Optional Accessories and Set Up Configuration (cont.)Outdoor Installation of the Unit (For Classic 40 and Classic 60)The unit ca

Page 17 - 2. Application Configuration

24INSTALLATION (cont.)Wall Thermostat Connection (Millivolt System ONLY: Option)Connecting Wall Thermostat to Unit1. Use with a single stage wall ther

Page 18

25INSTALLATION (cont.)Wall Thermostat Connection (Millivolt System ONLY: Option) (cont.)Connecting Wall Thermostat to Unit4. Set the wall thermostat t

Page 19

26INSTALLATION (cont.)Wall Thermostat Connection (Millivolt System ONLY: Option) (cont.)Connecting Wall Thermostat to Unit8. Install the wall thermost

Page 20

27INSTALLATION (cont.)Warning Signal Connection (Output Signal Terminal L+ and L-)The controller is equipped with a warning signal output relay type (

Page 21

28INSTALLATION (cont.)Warning Signal Connection (Output Signal Terminal L+ and L-) (cont.)Connecting Warning Signal from Controller3. Insert the warni

Page 22

29INSTALLATION (cont.)Fire Alarm Control Panel Connection (Input Signal Terminal E+ and E-)The controller is equipped with a normal open input signal

Page 23

OPERATION MANUALCLASSIC 40 and CLASSIC 60

Page 24

30INSTALLATION (cont.)Fire Alarm Control Panel Connection (Input Signal Terminal E+ and E-) (cont.)Connecting Fire Alarm Control Panel to Controller3.

Page 25 - GYWRCRHOB

31OPERATIONFeatures1. A digital electronic control panel, which allows the user to easily control the unit’s operation.2. Digital LED display that ind

Page 26

32OPERATION (cont.)Control PanelBefore operating the unit, it is important to familiarize yourself with the basic controls located on the control pane

Page 27

33OPERATION (cont.)Control Panel (cont.)LED Display DescriptionsIn normal operation, the LED displays the following descriptions.Note: The ROOM TEMP d

Page 28

34OPERATION (cont.)Operating ModesThe Classic 40 and Classic 60 can be operated in two modes, FAN ONLY and COOL. When in FAN ONLY mode, the unit circu

Page 29

35OPERATION (cont.)Operating in COOL Mode1. The unit can be operated in COOL mode by pressing the COOL ON/OFF button.Note: In COOL mode the unit can o

Page 30

36OPERATION (cont.)Self-Diagnostic CodesSelf-diagnostic codes are displayed on the control panel under the following conditions.Contact your MovinCool

Page 31 - OPERATION

37DAILY INSPECTION & MAINTENANCEClean the Air FiltersClean the air filters once a week. If the unit is used in a dusty environment, more frequent

Page 32 - OPERATION (cont.)

38DAILY INSPECTION & MAINTENANCE (cont.)In-Season/Off-Season Inspection & MaintenanceWARNING: To prevent an accident due to electrical shock,

Page 33 - Control Panel (cont.)

39DAILY INSPECTION & MAINTENANCE (cont.)In-Season/Off-Season Inspection & Maintenance (cont.)Off-Season1. Operate the unit in FAN ONLY mode fo

Page 34

Table of ContentsSERIAL NUMBER LOCATION AND IDENTIFICATION ... 2FOREWORD ...

Page 35

40TROUBLESHOOTINGCheck the following items before calling your MovinCool reseller or a qualified technician.CONDITION POSSIBLE CAUSE REMEDYUnit does n

Page 36 - Self-Diagnostic Codes

41TROUBLESHOOTING (cont.)If conditions persist after the above actions have been taken, turn the unit off, disconnect the power and contact your Movin

Page 37 - Filter Removal Method

42TROUBLESHOOTING (cont.)Installation Check SheetITEMS 9Installation Unit Check and make sure all screws are tight and unit is secured in place.Check

Page 38 - In-Season

43TECHNICAL SPECIFICATIONS*1: Rated at external static pressure 0.63 IWG (157 Pa).*2: Rated at external static pressure 0 IWG (0 Pa).*3: Rated at exte

Page 39 - Off-Season

44TECHNICAL SPECIFICATIONS (cont.)ITEMS/FEATURES Classic 40 Classic 60Safety DevicesCompressor overload protectorFan motor protectorAnti-freezing ther

Page 40

WARRANTY STATEMENTDENSO PRODUCTS AND SERVICES AMERICAS, INC. ("DENSO") warrants its MOVINCOOL Products only to the extent stated in its offi

Page 41

P/N: 484007-3621EN Second Issue: April 2013

Page 42 - Installation Check Sheet

5FOREWORDCongratulations on purchasing the MovinCool spot cooling system. This manual explains how to assemble, install and operate the MovinCool Clas

Page 43

6INVENTORY & ASSEMBLYInventoryClassic 40After unpacking your MovinCool unit, please check to make sure you have the following items:1. Classic 40

Page 44

7INVENTORY & ASSEMBLY (cont.)Inventory (cont.)Classic 60After unpacking your MovinCool unit, please check to make sure you have the following item

Page 45 - WARRANTY STATEMENT

8INVENTORY & ASSEMBLY (cont.)Assembly of Exhaust Duct (For Classic 60 ONLY)1. Remove the exhaust duct from the package.2. Install the exhaust duct

Page 46

9INSTALLATIONUnit OverviewClassic 40Classic 60EXHAUST DUCTCOOL AIR OUTLETAIR FILTERSCONTROL PANELPOWER CORDEXHAUST DUCTCOOL AIR OUTLETCONTROL PANELAIR

Commentaires sur ces manuels